sql

KWH Meter MK6N

Rp. 7,000,000
Last Updated
15 May 2024
Country Origin
Singapore
Minimum Order
1 Unit
Category
Kwh Meter

Kwh meterAccuracy


• Class 0.5S


• IEC62052-11, IEC62053-22


IEC62053-23


Measurement Modes


• Single Phase (3 Circuits)


• 3 Phase 3 Wire


• 3 Phase 4 Wire


Measured Energy Values


• 3 Elements, 4 Quadrants


• Import/Export Wh, varh and VAh


• Absolute Wh, varh and VAh


• Phase A, B, C or Total


Other Measured and


Displayed Values


• W, var, VA


• True RMS Voltage (3 Phase)


• True RMS Current (3 Phase)


• Power Factor


• Frequency


• Phasor Angles


Load Survey / Load Profile


• NEM Compliant


• Standard 400 day-channel capacity at


30 minute intervals


• Optional additional storage to increase


to over 2,500 day-channel capacity at


30 minute intervals


• Up to 50 Channels


• Per survey interval programmable from


1 second to 1 month


• Multiple independent surveys


• Energy, instantaneous readings and


pulsing inputs as potential survey


channel sources


• Ability to store average / minimum /


maximum values over interval duration


for individual channels


Time of Use


• 8 rates plus unified rate


• Up to 12 separate import and


export registers


• Up to 200 programmable


special days


• Daily, Weekly, Monthly, Yearly, Special


• 13 or more previous periods


• Block or Rolling Maximum Demand


• Time of Maximum Demand


• Configurable Billing Reset Button


Communications Options


• ANSI Type 2 Optical Port (ANSI


C12.18) or IEC 62056-21 (IEC 61107)


Optical FLAG Port


• RS232 (RTS/CTS and DTR/DCD)


• RS485 (2 or 4 wire multidrop)


• SCADA


• Modems (PSTN/GPRS/GSM/C DMA)


• Internal Modem Power Supply


• MV-9OTM Compatible


• PPP / GPRS


• MODBUS


• DNP3


• Master / Slave arrangement with up to


31 ‘Slave’ meters accessed through


one ‘Master’ gateway meter


Voltage


• Operating Range of 57.7/100 - 23 0/400V


• Burden of < 10VA per phase @ Vn


(3 Phase)


• Frequency of 45 to 65Hz


Current


• CT Range: 1(4)A, 5(10)A


• Short time over-current of 20 times


‘max for 0.5 seconds


• Burden of less than 0.5VA


per phase


Auxiliary Supply Options


• 240V, 110V Aux Only (other voltages


available on special order)


Pulsing Inputs / Outputs


• Maximum of 8 I/O with up to 8 outputs


(2 standard) or 6 inputs


• Output voltage - 5 - 220V DC,


12 - 240V AC


• Output current of 0.1A maximum


• Output pulse width 2 output


independent LEDs of lms to 250ms


• Programmable output polarity


• Input Voltages of 5, 12, 48, 110, 240V


AC / DC


• Time synchronised (optional)


Environmental


• Operating Range of -10 to +60°C


• Storage Range of -40 to +85°C


Time Clock


• Accuracy (internal) within 30 seconds


per month


• Backup time of 2 years without power


• Backup utilizing either lithium battery


or optional SuperCap


• Mains synchronised or internal crystal


time keeping. Mains synchronised


reverts to internal crystal on loss of


voltage on all phases


Data Storage


( Configuration, TOU Data and Load


Survey Data)


• FlashRAM


• Battery backed up RAM


Sag / Swell


• 5 Cycle Resolution


• Records time / date / phase / duration


and worst excursion


• Programmable trigger levels


LCD Display


• 16 Character by 2 line


alphanumeric display


• Programmable units, multipliers and


leading zeros


• Up to 64 user definable


screen displays


• Displays any available


meter parameter


Optional Functions


• Quality of Supply (QOS) features


• Waveform Capture


• Harmonic analysis to the


50th harmonic


• THD Measurement


• Fundamental energy measurement


Software


• EDMI EziView software available for


programming and reading of meter


(Runs on Windows 98/ME/NT/


2000/XP)


• EziView also allows offline


configuration of tariff programs and


all meter parameters, for later upload


to meters


Dimensions


• 292.5mm (L) x 175mm (W) x 94mm (D)


Equipment Failure


Alarms (EFAs)


A single user defined alarm condition


(via extensions) is available plus


pre-programmed alarms based


on numerous:


• Self-Checks


• Tamper and wiring checks


These Alarms Can:


• Turn on LED, LCD indicator or relay


output


• Record an event in the event log


• Trigger an event such as a remote


alarm, dial an emergency number,


send an SMS to a programmable


number or send alarm messages via


GPRS to a programmable server


Extensions for


Customer Applications


The Mk6N inherits the ability to use


Extensions to increase the functionality


of the standard metering platform. A


simple yet powerful scripting language


allows complex register manipulations


to be performed that can create


customized functions within the


meter without the need for a firmware


upgrade. EDMI is always developing


new extensions and we offer custom


extension creation for specific customer


needs. Contact us to find out more


about Extensions for the Genius range


of meters


Examples of currently available


Extensions for EDMI Genius


Energy Meters:


• Send SMS at percentage of


maximum demand


• Average power factor for billing period


• LCD menu system


• Magnetic tamper detection


• Power factor control extension


• Maximum demand control of loads via


pulsing outputs


• Average voltage / current / unbalance,


THD etc.


• Voltage Sag / Swell or Power Outage


• Voltage Quality


• Send SMS / GPRS Alarm on


Equipment Failure Alarm


• Detect Individual Phase VT Failures


Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1